{"product_id":"rain-bird-psr220ic-220v-universal-pump-start-relay","title":"Rain Bird PSR220IC 220V Universal Pump Start Relay","description":"\u003ch2\u003eRain Bird PSR220IC 220V Universal Pump Start Relay\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Rain Bird | \u003cstrong\u003eSKU:\u003c\/strong\u003e PSR220IC\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eSwitch a compatible 220-volt single-phase irrigation pump from a supported 24 VAC controller or decoder output with Rain Bird PSR220IC. The Universal PSR arrangement includes an additional ice-cube relay for supported two-wire applications. Its model-specific range is 3\/4 through 5 HP at the specified higher line voltage; it is not the 110-volt PSR110IC.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e220-volt single-phase pump line arrangement.\u003c\/li\u003e\n\u003cli\u003e24 VAC control connection.\u003c\/li\u003e\n\u003cli\u003eAdditional ice-cube relay for supported two-wire control applications.\u003c\/li\u003e\n\u003cli\u003eNEMA 3R steel enclosure with grounding provision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Uses\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStarting a correctly matched irrigation pump from a compatible control system.\u003c\/li\u003e\n\u003cli\u003eReplacing a matching Universal PSR after checking line voltage and controller or decoder output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eModel: PSR220IC; factory part: PS310002.\u003c\/li\u003e\n\u003cli\u003eMotor line voltage: 220 VAC nominal, single phase.\u003c\/li\u003e\n\u003cli\u003eController\/interface control connection: 24 VAC.\u003c\/li\u003e\n\u003cli\u003eModel-specific motor range: 3\/4 through 5 HP, with the required motor thermal protection.\u003c\/li\u003e\n\u003cli\u003eAdditional ice-cube relay for supported two-wire controller\/decoder applications.\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz.\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 3R, gray powder-coated steel.\u003c\/li\u003e\n\u003cli\u003eGrounding provision and quick-connect terminals.\u003c\/li\u003e\n\u003cli\u003ePump, controller\/decoder, branch-circuit and motor-protection equipment are separate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWidth: 6 inches.\u003c\/li\u003e\n\u003cli\u003eHeight: 6 inches.\u003c\/li\u003e\n\u003cli\u003eDepth: 4 inches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Installation Notes\u003c\/h3\u003e\u003cp\u003eChoose the 220-volt model for a matching motor supply and check the motor nameplate. Do not use a different voltage column from the shared relay-component table as permission to change the model’s specified line configuration.\u003c\/p\u003e\u003cp\u003eConfirm that the controller or decoder provides the required 24 VAC control arrangement. The ice-cube relay does not make the unit compatible with every decoder or a different control-voltage type.\u003c\/p\u003e\u003cp\u003eHave a qualified installer follow the supplied relay and motor wiring diagrams with all power disconnected. Keep the factory internal wiring intact and complete the specified grounding connection.\u003c\/p\u003e\u003cp\u003eProvide appropriate motor thermal-overload and circuit protection. Starting the pump on command is different from protecting it against every overload or operating fault.\u003c\/p\u003e\u003cp\u003eThe published Universal PSR installation guide applies to units built from January 2002 onward. Use the unit’s supplied diagram and obtain manufacturer guidance for an older installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003ch4\u003eIs 24 VAC the pump supply voltage?\u003c\/h4\u003e\u003cp\u003eNo. It is the controller\/interface control connection. PSR220IC is selected for a 220-volt motor line arrangement.\u003c\/p\u003e\u003ch4\u003eWhat motor size is listed for PSR220IC?\u003c\/h4\u003e\u003cp\u003eThe manufacturer’s model table lists 3\/4 through 5 HP for PSR220IC, subject to the specified supply and required motor thermal protection.\u003c\/p\u003e\u003ch4\u003eWhy does it have an ice-cube relay?\u003c\/h4\u003e\u003cp\u003eRain Bird includes the additional relay for supported two-wire controller\/decoder applications. Verify the exact controller output before installation.\u003c\/p\u003e\u003ch4\u003eDoes the relay replace motor overload protection?\u003c\/h4\u003e\u003cp\u003eNo. Provide the motor and circuit protection required for the actual installation; the pump-start function alone does not provide complete pump protection.\u003c\/p\u003e\n\u003ch3\u003eWhy Buy from Big Frog Supply?\u003c\/h3\u003e\u003cp\u003eChoose PSR220IC when the pump uses the 220-volt line arrangement and needs the Universal PSR ice-cube relay interface. The model-specific 5 HP maximum and separate 24 VAC control connection define that choice; they do not turn it into a universal supply-voltage relay. Confirm the motor voltage and the controller or decoder output before selecting it instead of PSR110IC or the standard dual-pole model.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is 24 VAC the pump supply voltage?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. It is the controller\/interface control connection. PSR220IC is selected for a 220-volt motor line arrangement.\"}},{\"@type\":\"Question\",\"name\":\"What motor size is listed for PSR220IC?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The manufacturer’s model table lists 3\/4 through 5 HP for PSR220IC, subject to the specified supply and required motor thermal protection.\"}},{\"@type\":\"Question\",\"name\":\"Why does it have an ice-cube relay?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Rain Bird includes the additional relay for supported two-wire controller\/decoder applications. Verify the exact controller output before installation.\"}},{\"@type\":\"Question\",\"name\":\"Does the relay replace motor overload protection?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Provide the motor and circuit protection required for the actual installation; the pump-start function alone does not provide complete pump protection.\"}}]}\u003c\/script\u003e","brand":"Rain Bird","offers":[{"title":"Default Title","offer_id":68318481252579,"sku":"zgd1794042380855","price":60.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/2961\/4819\/files\/rain-bird-psr220ic-220v-universal-pump-start-relay_1.jpg?v=1794042387","url":"https:\/\/dewverna.com\/products\/rain-bird-psr220ic-220v-universal-pump-start-relay","provider":"Dewverna","version":"1.0","type":"link"}